Technical characteristics
■ automatic coupling decoupling network, free switching common differential mode test, one key test can be realized by setting common differential mode ratio;
■ external network, can cooperate with any brand lightning surge / ringing wave generator to complete automatic lightning surge test;
■ modular architecture, easy to maintain and upgrade.
IEC61000-4-5 ed.3 IEC61000-4-12
Lightning surge coupling decoupling network |
|
Parameter |
DN-533P |
Polarity |
Surge comprehensive wave, ringing wave |
Max input surge voltage |
10kV |
Max input surge currency |
5kA |
Phase synchronization |
Asynchronous/synchronous 0 to 359° |
Coupling mode |
Common mode, differential mode |
Residual voltage |
Not more than 15% of coupling voltage |
Capacity of tested equipment |
三相 AC440V/32A DC240V/32A |
Size |
CN-533P:19''/6U DN-533P:19''/4U |
Weight |
65kg |