Technical features:
7” color capacitive touch screen provides a friendly and powerful human-machine control interface;
Highly integrated design saves test space, and one machine can complete all user testing needs.
The pulse peak is above 5 kV and the surge peak is above 6 kV, providing users with sufficient test margin;
Surge and pulse groups all use high-voltage and high-speed semiconductor switches, which can produce excellent interference waveforms and interference characteristics;
Rich and complete communication interface design, standard configuration of RS485, USB, LAN, wireless WIFI;
Built-in calibration factor self-calibration function, convenient for users to calibrate by themselves;
The interface allows you to quickly and directly write test programs, making test operations intelligent;
Model | LCG-5411 |
Interference Type |
Electrical fast transient pulse group immunity, lightning surge immunity, pulse magnetic field immunity, single-phase voltage drop immunity, DC voltage drop immunity, power frequency magnetic field immunity |
Electrical fast transient burst test parameters |
|
Output voltage polarity |
Positive/negative/ positive and negative automatic switching |
Output voltage |
200 V ~500 0 V±10% 10V step |
Pulse frequency |
0.1 kHz~1000 kHz 0.1 kHz/step ±20% |
Source 50 Ω calibration characteristics |
Peak voltage: (set voltage/2) ±10% Rising edge : 5 ns±30% Half pulse width: 50 ns ± 30% pulse leading edge |
Source 1 kΩ calibration characteristics |
Peak voltage: (set voltage*1000/1050)±20% Rising edge : 5 ns±30% Half pulse width: 3 5 ns~150 ns |
CD N- terminal 50 Ω calibration characteristics |
Peak voltage: (set voltage/2) ±10% Rising edge : 4 ns~7 ns Half pulse width: 30 ns~60 ns |
Pulse train period |
10~99999 ms 1 ms step |
Testing time |
1 ~ 99999 s , 1 s step |
DC Capacitance |
10 nF ± 20% |
Output format |
5 0Ω BNC coaxial connector |
CDN coupling capacitor |
Common mode coupling capacitor: 33 nF |
CDN input residual voltage |
Less than 10 % of the set voltage value (EUT line input and output open circuit) |
CDN can be coupled to the path |
L/N/PE/L&N/L&PE/N&PE/L&N&PE |
Lightning surge test parameters |
|
Output voltage polarity |
Positive/negative/ positive and negative automatic switching |
Output voltage |
200 V ~61 0 0 V±10% 10 V step |
Output Impedance |
2Ω , 12Ω, 42Ω ±10% |
Output Current |
50A ~3050A ± 10% |
Source output voltage waveform |
Rising edge : 1.2 µs ±30% Half width: 50 µs ±20% |
Source output current waveform |
Rising edge : 8 µs ±20% Half width: 20 µs ±20% |
Source output overshoot |
Less than 30% of peak voltage /current |
Repeat time |
1 0 ~9999 s |
Output voltage module function |
Peak value accuracy: ± 10% is displayed on LCD , and real-time waveform can be output through BNC interface on the front panel. Type, 1 0 V@6 kV |
Output current module function |
Peak value is displayed on LCD Accuracy: ±10%, real-time waveform can be output via BNC interface on the front panel 1 0 V@3 kA |
CDN coupling parameters |
Differential mode : 18 µF Common mode: 9 µF +10 Ω |
CDN can be coupled to the path |
LN/NL/L-PE/N-PE/L&N-PE |
CDN input residual voltage |
Not exceeding 15% of the surge voltage or 2 times the peak voltage of the EUT power supply |
CDN Differential mode open circuit voltage/ short circuit current |
Voltage: 100 V~6100 V±10% Current: 50 A~3050 A±10% |
CDN differential mode open circuit voltage waveform |
Rising edge : 1.2 µs ±30% Half width: 40 µs ~ 60 µs |
CDN differential mode short-circuit current waveform |
Rising edge : 8 µs ±20% Half width: 20 µs ±20% |
CDN common mode open circuit voltage/ short circuit current |
Voltage: 100 V~6100 V±10% Current: 8.33 A~508 A |
CDN common mode open circuit voltage waveform |
Rising edge : 1.2 µs ±30% Half width: 25 µs ~ 60 µs |
CDN common mode short circuit current waveform |
Rising edge : 2.5 µs ±30% Half width: 25 µs ±30% |
Voltage drop at CDN rating |
Less than 10% of rated voltage when operating at rated current |
Angle injection |
Asynchronous /synchronous, 0~359 degrees, step value is 1 degree |
AC voltage drop test parameters (MVR-16 voltage regulator is required) |
|
Test voltage range |
AC:264Vmax |
Test frequency range |