LCG-5411 is a new intelligent, highly integrated multifunctional combination generator developed by Lingshi. It integrates multiple test items such as electrical fast transient pulse group test, lightning surge test, single-phase AC voltage drop, DC voltage drop, pulse magnetic field, etc. It has full-color capacitive touch screen control and built-in coupling and decoupling network. The product is mature and provides a reliable basis for users

Technical features:

  • 7” color capacitive touch screen provides a friendly and powerful human-machine control interface;

  • Highly integrated design saves test space, and one machine can complete all user testing needs.

  • The pulse peak is above 5 kV and the surge peak is above 6 kV, providing users with sufficient test margin;

  • Surge and pulse groups all use high-voltage and high-speed semiconductor switches, which can produce excellent interference waveforms and interference characteristics;

  • Rich and complete communication interface design, standard configuration of RS485, USB, LAN, wireless WIFI;

  • Built-in calibration factor self-calibration function, convenient for users to calibrate by themselves;

  • The interface allows you to quickly and directly write test programs, making test operations intelligent;

Meet the standards:
IEC61000-4-4 IEC61000-4-4 Ed.3/Ed.2 EN61000-4-4 GB/T17626.4 IEC61000-4-5 Ed.3 EN61000-4-5 GB/T17626.5 IEC61000-4-8 EN61000-4-8 GB/T17626.8 EN61000-4-9 GB/T17626.9 IEC61000-4-11 EN61000-4-11 GB/T17626.11 IEC61000-4-29 GB/T 17626.29 GB/T 9706.2 GB 1683 8 GB4343.2 IR46 GB/T18595
application area:
Industrial equipment, power meters, vehicle electronics, medical equipment, lighting fixtures, communication transmission, audio and video equipment, low-voltage electrical appliances, electronic components, power tools, information technology equipment, rail transit and aerospace electrical appliances, instruments and meters
technical parameter:
Model LCG-5411

Interference Type

Electrical fast transient pulse group immunity, lightning surge immunity, pulse magnetic field immunity,  single-phase voltage drop immunity, DC voltage drop immunity, power frequency magnetic field immunity

Electrical fast transient burst test parameters

Output voltage polarity

Positive/negative/ positive and negative automatic switching

Output voltage

200  ~500 0  V±10% 10V  step

Pulse frequency

0.1  kHz~1000 kHz 0.1 kHz/step ±20%

Source 50 Ω calibration characteristics

Peak voltage: (set voltage/2) ±10%

Rising edge : 5 ns±30%

Half pulse width: 50  ns ± 30% pulse leading edge

Source 1  kΩ calibration characteristics

Peak voltage: (set voltage*1000/1050)±20%

Rising edge : 5 ns±30%

Half pulse width: 3 5 ns~150 ns

CD N- terminal 50 Ω calibration characteristics 

Peak voltage: (set voltage/2) ±10%

Rising edge : 4 ns~7 ns

Half pulse width: 30 ns~60 ns

Pulse train period

10~99999 ms 1 ms step

Testing time

~ 99999 s , 1 s step

DC Capacitance

10  nF ± 20%

Output format

0Ω BNC  coaxial connector

CDN coupling capacitor 

Common mode coupling capacitor: 33 nF

CDN input residual voltage 

Less than 10 % of the set voltage value (EUT line input and output open circuit)

CDN can be coupled to the path 

L/N/PE/L&N/L&PE/N&PE/L&N&PE

Lightning surge test parameters

Output voltage polarity

Positive/negative/ positive and negative automatic switching

Output voltage

200  ~61 0 V±10% 10 V  step

Output Impedance

2Ω  12Ω, 42Ω ±10%

Output Current

50A  ~3050A  ± 10%

Source output voltage waveform

Rising edge : 1.2  µs ±30%    Half width: 50  µs ±20%

Source output current waveform

Rising edge : 8  µs ±20%    Half width: 20  µs ±20%

Source output overshoot

Less than 30% of peak voltage /current

Repeat time

~9999 s

Output voltage module function

Peak value accuracy: ± 10%  is displayed on    LCD  , and real-time waveform can be output through BNC  interface on the front panel.

Type, 1 0 V@6 kV

Output current module function

Peak value is displayed on LCD  Accuracy: ±10%,  real-time waveform can be output via BNC  interface on the front panel

0 V@3 kA

CDN coupling parameters 

Differential mode :     18  µF Common mode: 9  µF +10 Ω

CDN can be coupled to the path 

LN/NL/L-PE/N-PE/L&N-PE

CDN input residual voltage 

Not exceeding 15% of the surge voltage or 2 times the peak voltage of the EUT power supply

CDN Differential mode open circuit voltage/  short circuit current 

Voltage: 100 V~6100 V±10%     Current: 50 A~3050 A±10%

CDN differential mode open circuit voltage waveform 

Rising edge : 1.2  µs ±30%    Half width: 40  µs ~  60 µs

CDN differential mode short-circuit current waveform 

Rising edge : 8  µs ±20%    Half width: 20  µs ±20%

CDN  common mode open circuit voltage/  short circuit current

Voltage: 100 V~6100 V±10%     Current: 8.33 A~508 A

CDN common mode open circuit voltage waveform 

Rising edge : 1.2  µs ±30%    Half width: 25  µs 60 µs

CDN common mode short circuit current waveform 

Rising edge : 2.5  µs ±30%    Half width: 25  µs ±30%

Voltage drop at CDN rating 

Less than 10% of rated voltage when operating at rated current

Angle injection

Asynchronous /synchronous, 0~359 degrees, step value is 1 degree

AC voltage drop test parameters (MVR-16 voltage regulator is required)

Test voltage range

AC:264Vmax

Test frequency range