Products
Products
Lightning Surge/Ring Wave Power Line Coupling and Decoupling Network CDN-5320H Return
Product overview
As the main component of the lightning surge/ring wave test system, the lightning surge/ring wave coupling and decoupling network directly determines the consistency and repeatability of the test results. The power line coupling and decoupling network developed and produced by Lingshi meets the calibration requirements for the output waveform in IEC61000-4-5 Ed.3 and IEC61000-4-12, providing an accurate evaluation method for product electromagnetic compatibility immunity testing.

Technical features

■ Automatic coupling and decoupling network, free switching of common-differential mode test, and one-key test by setting the common-differential mode ratio; 

■ Network external, can automatically switch between lightning surge and ring wave testing; 

■ Any type of coupling and decoupling network is backward compatible with calibration requirements; 

■  Emergency stop function for EUT circuit; 

■  One machine is compatible with 16A~200A test; 

■  EUT overload and short circuit protection function;  

■  Compatible with ring wave and ANIS standards

Meet the standards:
IEC61000-4-5, Ed.3 EN61000-4-5, GB/T17626.5, ITU K.21, ITU K.20, ANSI C 62.41 
application area:
New energy vehicles, charging piles, wind power, solar energy, industrial equipment, power meters, vehicle electronics, medical equipment, lighting fixtures, communication transmission, audio and video equipment, low-voltage electrical appliances, electronic components, power tools, information technology equipment, rail transit and aerospace electrical appliances, instruments and meters
technical parameter:
Model

CDN-5320H-32AC

CDN-5320H-100AC

CDN-5320H-200AC

Coupling waveform

Surge wave, ringing wave

Input surge voltage

12kV

Input surge current

6kA

Phase

Asynchronous; synchronous 0-359º

Coupling method

Common mode, differential mode

Residual voltage

Not exceeding 15% of the surge voltage or twice the rated EUT power supply voltage

Coupling Path

L1 , L2 , L3 , N , PE , any line - line, line - ground phase angle superposition

Coupling parameters

Differential mode 18µF ; Common mode 9µF+10Ω

Test equipment capacity

AC three-phase 900V/32A DC 1500V/32A

AC three-phase 900V/100A DC1500V/100A

AC three-phase 900V/200A DC1500V/200A

CDN differential mode open circuit voltage waveform

Rising edge: 1.2µs±30% Half width: 40µs~60µs

32A gear position:

Rising edge: 1.2µs±30%

Half width: 40µs~60µs

100A gear:

Rising edge: 1.2µs±30%

Half width: 30µs~60µs

32A gear position:

Rising edge: 1.2µs±30%

Half width: 40µs~60µs

200A gear:

Rising edge: 1.2µs±30%

Half width: 30µs~60µs

CDN differential mode short-circuit current waveform

Rising edge: 8µs±20% Half width: 20µs±20%

CDN common mode open circuit voltage waveform

Rising edge: 1.2µs±30% Half width: 25µs~60µs

32A gear position:

Rising edge: 1.2µs±30%

Half width: 25µs~60µs 

100A gear:

Rising edge: 1.2µs±30%

Half width: 15µs~60µs

32A gear position:

Rising edge: 1.2µs±30%

Half width: 25µs~60µs

200A gear:

Rising edge: 1.2µs±30%

Half width: 15µs~60µs

CDN common mode short circuit current waveform

Rising edge: 2.5µs±30% Half width: 25µs±30%

General parameters

Working power supply

AC 220V±10% 50/60Hz 45W

size

19"/22U

Humidity range

30%-60% (operating conditions)

Safety indicator function

EUT circuit emergency stop function, short circuit protection, overload protection

Random standard

Host, test line, power cord, test report, instruction manual

parts:
Video playback:

Copyright:Shanghai Lioncel Electromagnetic Technology Co., Ltd (2020)